Hoje lançámos uma nova versão de firmware para o GroNode, o módulo principal do sistema GroLab™. Em baixo poderás encontrar a lista de alterações desta versão.
Lista de Alterações:
- Implemented single time execution mode to Schedules/Alarms;
- Implemented independent device Security Cooldown time to prevent rapid switching in sensitive devices (ex. HPS);
- Implemented Custom Time alarms, alarms that only act during a desired period of the day;
- Improved RF communications with better buffer management and CRC enhancement;
- Improved GroLab modules registration process;
- Improved setting GroNode clock, more validations (to prevent erroneous date/time definitions);
- Improved data logs management;
- Improved GroLab modules data checking, now it will have a non blocking behavior (improving alive/not alive);
- Fixed minor issues related with e-mail notifications templates;
- Fixed not closing SMTP when connection lost, causing e-mail notifications operation to block until a GroNode Reset;
- Fixed data logs frame count when dumping all data to GroLab Software;
- Fixed rewrite speed command constantly setting the speed;
- Persistence Alarms & Schedules now ease of the RF Network by having a timeout to retry the persistence;
- If GroNode is DHCP, upon wake up the default IP is set 10.0.0.101 (this forces DHCP reacquire);